1812 Membrane Housing for Efficient Reverse Osmosis Systems

Product Details
Customization: Available
Usage: RO Machine
Motive Force: Pressure
Still deciding? Get samples of $ !
Request Sample
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
ODM Services
The supplier provides ODM services
Full Customization
The supplier provides full customization services
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (17)
  • 1812 Membrane Housing for Efficient Reverse Osmosis Systems
  • 1812 Membrane Housing for Efficient Reverse Osmosis Systems
  • 1812 Membrane Housing for Efficient Reverse Osmosis Systems
  • 1812 Membrane Housing for Efficient Reverse Osmosis Systems
  • 1812 Membrane Housing for Efficient Reverse Osmosis Systems
  • 1812 Membrane Housing for Efficient Reverse Osmosis Systems
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Our Factory
  • Company Profile
  • Certifications
  • Exhibition
  • FAQ
Overview

Basic Info.

Model NO.
1812 Membrane Housing
Style
Tube
Performance
Efficient Filtration
Certification
CE, GS, RoHS
Application
Hotel, Commercial, Household
Power Source
Manual
Model Number
1812 Membrane Housing
Product Name
Reverse Osmosis Membrane
Color
White
Size
1.8*12(Inch)
Keyword
Domestic RO Membrane
Function
Reverse Osmosis Purifier Part
Operating Principle
RO
After Warranty Service
Online Support
Transport Package
50PCS/Carton
Specification
55*55*35
Trademark
HJC
Origin
China
Production Capacity
500000pieces/Year

Product Description

Product Description

Model Port Size(Feedwater/Drain water/Pure water) Material
1812  1/4" /4" 1/4" Food graded polypropylene
3012  3/8" /4" /4"
3013  3/8" 3/8" /4"
3213  3/8" 3/8" 3/8"
10"BIG   1"1.5"  
20"BIG   1"1.5"  
20"NORMAL   1/2"3/8"1"    

Standard Size
Introducing the Membrane Solutions 1812/3012/3013/3213 Reverse Osmosis Housing! With its universal size, this housing seamlessly integrates with a variety of standard-sized residential RO membranes. Embrace compatibility with an impressive range from 100 GPD to 800 GPD, ensuring versatility for all your purification needs.

Durable Construction
Crafted from robust FRP (Fiber Reinforced Polypropylene), our membrane housing boasts enhanced thickness, providing superior pressure resistance and remarkable anti-explosion features. Its excellent heat insulation and resistance to a spectrum of corrosive substances—like acids, alcohol, ammonia, oils, and plating solutions—promise exceptional durability and reliability.

Efficient Leakage Protection
Engineered with precision, our housing features a thickened unibody design and dual o-ring sealing for superior leakage prevention. This guarantees not only drinking safety but also compression resilience and explosion-proof strength, elevating your water purification experience to new heights.

Wide Application
Revitalize your home or office with an advanced reverse osmosis filtration system! Experience the pleasure of pure water, or incorporate it into your DIY projects, whether for drinking purposes or for gathering concentrated maple sap. Our housing is your gateway to endless possibilities.

Package Includes
1 x Housing,
3 x Elbow Fittings
1 x Wrench

How to Change RO Housing and Membrane?
1. Start by turning off both the feed water supply line valve to the RO system and the valve on the water tank to ensure safety.
2. Open the RO faucet and let the pressure release, ensuring a smooth transition for the next steps.
3. Carefully remove the blue safety clip, depress the collect, and disconnect the tubing from the membrane housing with precision.
4. Employ the wrench to expertly remove the membrane housing cap, preparing for the membrane change.
5. Use pliers to gently extract the used membrane, then discard it. Insert the new membrane, ensuring the end with two small washers goes in first. Push securely until it seats perfectly into the housing.
6. Securely replace and tighten the membrane housing cap, reconnect the tubing, and reattach the blue safety clip for a complete, leak-free setup.
Note: Should you encounter difficulty in replacing the housing cap, gently twist the RO membrane to seat it correctly to the pure water outlet, ensuring proper alignment.

Detailed Photos

1812 Membrane Housing for Efficient Reverse Osmosis Systems
1812 Membrane Housing for Efficient Reverse Osmosis Systems1812 Membrane Housing for Efficient Reverse Osmosis Systems

Our Factory

1812 Membrane Housing for Efficient Reverse Osmosis Systems1812 Membrane Housing for Efficient Reverse Osmosis Systems

Company Profile


Sandmonk Technology Co., Ltd. (SAND.K) stands at the forefront of water environmental technology, driving innovation with a passionate commitment. By harnessing a cutting-edge international supply chain, we infuse the industry with vibrancy and expertise. Our services encompass a comprehensive, one-stop solution for essential components. Tailored for small to medium-sized equipment manufacturers, our exceptional artistry utilizes cross-border e-commerce to reach global customers across developing markets, offering unparalleled service.
Boasting independent R&D capabilities and robust manufacturing prowess, we are leaders in innovation, pushing the boundaries and advancing the field continuously. Through meticulous data analysis, we customize solutions for areas grappling with high salinity water issues, adapting our expertise to meet specific local needs and challenges effectively.
Our versatile solutions cover seawater desalination, waste leachate treatment, drinking water purification, and wastewater reuse, offering a holistic approach to tackling water challenges head-on. Moreover, our unparalleled cost advantage ensures we deliver exceptional value and excellence, setting new standards within the industry.

1812 Membrane Housing for Efficient Reverse Osmosis Systems

Certifications

1812 Membrane Housing for Efficient Reverse Osmosis Systems

Exhibition

1812 Membrane Housing for Efficient Reverse Osmosis Systems

FAQ

QUESTION ANSWER
 Are you a factory or trading company? Yes, we have our own factory.
Can you offer OEM service? Yes, OEM is OK.
Can I get samples from you factory? Sure.  We are pleased to.
What would you do if some quality problem occur? We will be responsible to all quality problem.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier